BEA 10MATRIX Manuale Utente

Navigare online o scaricare Manuale Utente per Misurazione, test & controllo BEA 10MATRIX. 3. matrix_en Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 2
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
LED
SIGNAL
DIGITAL INDUCTIVE LOOP SENSORS
MATRIX USER’S GUIDE
Technology inductive loop
Tuning automatic
Detection mode presence
Presence time 1 min to infinity (permanent
presence) with 250 steps
Pulse time output 100 ms or 500 ms
Inductance range 20 µH to 1000 µH
Frequency range 20 kHz to 130 kHz
Frequency steps 4 for single loop
2 for dual loop (for each loop)
Sensitivity (ΔL/L) 0.005% to 0.5% with 250 steps
Reaction time 25 ms for single loop
50 ms for dual loop (each channel)
Power supply (depending on model)
12-24 AC/DC ±10%
230 V AC ±10%
90 ----->125 V AC ±0%
Mains Frequency 48 to 62 Hz
Power Consumption < 2.5 W
Storage temperature
range –30°C to +70°C
Operating temperature
range –30°C to +40°C
Degree of protection IP40
2 Output relays (free potential change-over
contact)
max contact voltage : 230 VAC
max contact current : 5A (resistive)
LED indicators
1 green LED : power
1 red LED : Loop status 1
1 red LED : Loop status 2
Protections
loop insulation transformer
zener diodes
gas discharge clamping
Connection standard 11-pin round
connector 86CP11
Dimensions 77mm (H) x 40mm (W) x 75mm (D)
Weight < 200gr
Product compliance
R&TTE 1999/5/EC
EMC 2004/108/EC
UL listed equipment for UL 508
A. CABLE SPECIFICATIONS FOR LOOP AND FEEDER
1.5mm
2
cross section area
Multi-strand cable
Insulation material : PVC or Silicone
For the feeder cable, the wire must be twisted at least 15 times by meter
Feeder for long runs used for foil screened cable is recommended (earth at equipment end only)
The feeder cable must be firmly fixed to avoid any false detection (max length : 100 m)
Waterproof cable junction box is required
B. LOOP GEOMETRY
With two adjacent loops connected to a dual channel sensor, it is possible for
these loops to share a common slot, if so required.
As the channels are multiplexed, no interference will occur
Avoid large loops or long feeder (max 100 m), the sensitivity will be affected
Power LED
Dip Switches
Detection state LED
(only with dual loop)
Detection state LED
Presence time
adjustment
Sensitivity adjustment
potentiometer
(only with dual loop)
Sensitivity adjustment
potentiometer
Ea
Eb
Feeder cable
L
The MATRIX Digital Inductive Loop Detector range is the ideal solution for parking barrier control, motorized gates and
doors, vehicle access control and industrial control systems.
The MATRIX range is a high performance single or dual channel vehicle detector packaged in a compact housing, the
connection is made with an industrial standard 11-pin round connector.
Six versions listed below are available, single or dual channel, and 3 possibilities for the power supply :
MATRIX-S110 : Single loop detector with 110 to 120 V AC power supply
MATRIX-S220 : Single loop detector with 220 to 240 V AC power supply
MATRIX-S12-24 : Single loop detector with 12 to 24 V AC/DC power supply
MATRIX-D110 : Dual loop detector with 110 to 120 V AC power supply
MATRIX-D220 : Dual loop detector with 220 to 240 V AC power supply
MATRIX-D12-24 : Dual loop detector with 12 to 24 V AC/DC power supply
TECHNICAL
SPECIFICATIONS
DESCRIPTION
OF
THE SENSOR
LOOPS
INSTALLATION
TIPS
APPLICATIONS
42-0570-V1 01/08
1 Green LED shows when the module is powered
2 Red LEDs give
the corresponding loop detection state in normal situation
the value of the oscillation frequency measurement or an error message on power ON
In normal situation the red LED stays ON as long as the loop detects any metallic object.
On power ON the sensor measures the oscillation frequency of each loop. The result of this measurement is displayed using
the corresponding red LED. The amount of blinking indicates the tens value of the frequency. For example 4 short flashes
correspond to a frequency between 40 kHz and 49 kHz. After this message the LED goes back to normal display.
If the loop oscillation frequency falls outside the limits set between 20 kHz and 130 kHz the red LED displays an error
message and the sensor activates the corresponding relay. The blinking frequency shows the type of error according to the
next table. The sensor will stay in this state until the problem is cleared and the frequency goes to the right range.
Remark : The sensor launches automatically a learning process if the oscillation frequency changes more than 10% in
comparison with the measurement value.
Loop frequency error LED display
Oscillation frequency too LOW or loop open LED blinking at 1Hz
Oscillation frequency too HIGH LED blinking faster at 2 Hz
Loop shorted or no oscillation LED blinking slower at 0.5 Hz
SYMPTOM
The loop detector will not work
The green LED is off
The loop detector will not work
The red LED is flashing slowly
(0.5 Hz)
The loop detector will not work
The red LED blinks at either 1Hz or
2Hz
The loop LED is detecting properly but
the contact is not made
Dip switches 5 to 8 are not responding
properly
PROBABLE CAUSE
There is no power supply to the loop
detector
The corresponding loop is shorted
The frequency of oscillation falls
outside the allowed range
Bad connection of the relay contacts
Their function varies according to
dip switch #10 setting
CORRECT ACTION
Check power supply
Check the loop cable
Adjust frequency with dip switches
or change loop turns
Check relay connections
Check the appropriate loop mode
required and adjust dip switch #10
Dual Loop Configuration A
Frequency adjustment for loop A for single loop detector
Dip Switch #1 Dip Switch #2 Loop frequency
OFF OFF High
ON OFF Mid High [High –20%]
OFF ON Mid Low [High – 25%]
ON ON Low [High – 30%]
Loop A
Loop A
Loop B
Relay A
Relay B
(non-directional mode)
Relay B
(directional A— B mode)
Pulse on entry B
Pulse on exit B
Pulse on entry A Pulse on exit A
Loop B
Loop A Loop B
Pulse on entry B
Pulse on exit B
Pulse on entry A Pulse on exit A
Dual Loop Configuration B
Loop A
Loop B
Relay A
Relay B
(non-directional mode)
Relay B
(directional A— B mode)
Pulse on entry B
Pulse on exit B
Pulse on entry A Pulse on exit A
Pulse on entry B
Pulse on exit B
Pulse on entry A Pulse on exit A
TROUBLE-
SHOOTINGS
Main connector
(86CP11)
The declaration of conformity and other technical documentation are available on our website or can be requested by phone or mail.
BEA S.A – LIEGE Science Park – Allée des Noisetiers, 5 B-4031 Angleur – Tel. +32 4 361 65 65 – Fax +32 4 361 28 58 – [email protected] – www.bea.be
Vedere la pagina 0
1 2

Sommario

Pagina 1 - MATRIX USER’S GUIDE

LED SIGNALDIGITAL INDUCTIVE LOOP SENSORSMATRIX USER’S GUIDETechnology inductive loopTuning automatic Detection mode presencePresence time 1 min to inf

Pagina 2 - ADJUSTMENTS

Configuration #3Dual loop in combined modeOFF ONHigh (loop A) Low (loop A)[High –30%]High (loop B) Low (loop B)[High –30%]Active mode

Commenti su questo manuale

Nessun commento